HZKS-3RAutomatic open flash point and ignition tester flash point analysis machine

I. Overview

ZKS-3R automatic open flash point ignition point tester is designed and manufactured in accordance with the requirements specified in the People's Republic of China standard GB/T3536ASTMD92 "Petroleum Products Flash point and ignition point determination (Cleveland open cup method) and GB/T267-1988, ASTMD92 Petroleum products flash point and ignition point determination (open method)

Model

HZKS-3R

Name

Automatic open flash point and ignition tester

Test Project

It can meet the requirement of petroleum, chemical, railway, aviation, electric power, commodity inspection and scientific research institutes for petroleum product testing.

Conform Standard

GB/T 3536, GB/T267-1988, ASTMD92

Technical characteristics

Unmarked keyboard, for predictable temperature, sample label, atmospheric pressure, test date and other parameters, with a prompt menu, guided input function

 

II. Instrument Characteristics

1. The instrument adopts color LCD large screen display, English interface, no identification keyboard, for predictable temperature, sample label, atmospheric pressure, test date and other parameters, with a prompt menu, guided input function.

2. Simulation tracking display temperature rise and experimental time function curve, with English error operation software prompt modification function, with test date, test time and other parameters prompt function

3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value

4. Differential detection, automatic correction of system deflection

5. Scan, detect, print data automatically completed, the test arm automatically rise and fall

6. Electronic ignition, forced air cooling

7. Automatic ignition without air source, improve the safety of the test

 

III. Main technical indicators and parameters

1. Imput power: AC220V±10%, 50Hz

2. Temperature measurement range: room temperature ~400°C

    Repeatability: flash point ≤150°C error ±3°C

Resolution: 0.1°C; Accuracy: 0.5%

3. Heating rate: comply with GB/T3536 standard

4. Ignition mode: electronic ignition, gas flame 3mm~4mm;

5. Ambient temperature :(10~40)°C

6. Relative temperature: ≤80%